Is there a way to reset the CCU or EUM remotely?


Print
Save to list
E-mail
Subscribe
Created 2007-03-29
Modified 2008-03-17
Views 2834
Author Jeff
If the CCU or the EUM can be accessed with SNMP, you should be able to reset the radios using Wave Rider’s GlobalReset MIBs.

The MIB names and OIDs are as follows:

CCU: ccuGlobalReset , OID 1.3.6.1.4.1.2979.11.1.8.0

EUM : eumGlobalReset , OID 1.3.6.1.4.1.2979.12.1.8.0

The default  community string for CCU and EUMs is not configured. To use  this utility you will need to configure the SNMP Write community string.  The command to configure the snmp write community string is "snmp community add <community> write"

You may use any SNMP tool, that sends the standard and individual “set” data.

Links that offers SNMP tools:

http://software.ccschmidt.de/#snmpgetset

http://www.fineconnection.com/Download.htm

EX : Resetting a CCU using finesnmpset where the CCU write community string is "test".

C:\finesnmpset 10.32.0.162 test 1.3.6.1.4.1.2979.11.1.8.0 integer 1




Related Articles
What is the latest SNMP MIBs for the LMS8000, CCU8000, CCU8010, NCL8000, CCU3100, EUM3005, EUM3006, MMT9000
Click here for the latest SNMP MIBS for LMS8000, CCU8000, CCU8010, NCL8000, CCU3100, EUM3005, EUM3006, MMT9000.
How do you set the current time and date on the OBR3500?
Normally this setting is done in "System Settings" under "System Tools"; however, a bug has been found that the OBR does not keep the NTP IP address. A...
What is the latest SNMP MIBs for the LMS4000, CCU3000, EUM3000, EUM3003, EUM3004, NCL1900
Click here for the latest SNMP MIBS for LMS4000, CCU3000, EUM3000, EUM3003, EUM3004, NCL1900.